Designed a new PVC waterproofing system which was loose-laid over the existing stone within the fountains, and covered the PVC membrane with pavers to minimize the aesthetic impact
Designed a cold applied, modified bitumen waterproofing system for the planters
Designed negative side waterproofing repairs, consisting of expanding polyurethane grout and cementitious grout for sub-grade areas of the building